To Go… or Not To Go… (That is the question)

 

During my recent trip to the S.C. Fire Academy for the 2013 Kill the Flashover research fires, I came away with one aspect as to the importance of thermal imaging and the fire attack that rocked my paradigm. It is referred as the GO..NO TEST. This is worthy of reading brothers so don’t stop here..

Typically, most fire service agencies train firefighters on Thermal Imaging Cameras (TIC) for a variety of uses related to fireground operations but few utilize the TIC for fire attack for gaining insight into the hostile environment you are preparing to engage upon.

Most TIC imagers have the capability to determine temperatures by placing a small cross-hair or “dot” onto a surface to determine temperatures. In a high temperature environment (greater than 500 degrees F) the TIC will indicate a red or orange color or numeric value for the surface being surveyed. (In this case, the ceiling)

Normally, this technique is used in overhaul operations but let’s discuss using the TIC in a fire attack mode as a life-saving…better yet.. a firefighter saving technique.

The “dot” or cross-hair on the TIC is aimed to the ceiling to gain a temperature reading of the surface of the ceiling and some particulate matter from combustion. It does not measure the temperature of the smoke.

The GO..or NO GO Test should be used by any fire attack, search, or vent team entering a working fire environment. It begins by the officer of the team directing the crew to prepare for the attack by gathering needed equipment. The officer and the crew should complete a 360 degree look at and into the structure using the TIC to determine hotspots (for possible fire locations), potential exits, other hazards, and close any doors that may be contributing towards fire development or creating a Air /Flow Path in order to slow fire progression and limit fire extension.

Upon completing the 360 walk-around, the officer quickly scans the exterior of the door prior to entry. This provides a quick look at temperatures of the door being used for entry. If a high temperature (above 500 degrees) is identified on the door from the exterior, chances are an eminent flashover is waiting for you on the other side once the doors is opened. This is a “NO GO” situation and the attack should be delayed until a hoseline is in place and can be discharged prior to entering the structure. Why you may ask?

If there are high heat signatures indicated on the exterior of entry point, most likely there are significant amounts of unburned gases (fuels) in the hallway that are too rich to burn. This is also known as a “plug”. When you open the door for entry the environment that was once too rich to burn has now been provided an exhaust point, for which, the environment has changed from a too rich environment into a flammable range and combined with the replenishment of oxygen into this environment and with an ignition source down the hallway can result in a flashover condition seconds into your search or fire attack.

So… back to the TIC…

Prior to opening the door, have the hose crew “condition/cool the door and surrounding area. I know… sounds crazy. This method of pre-wetting provides us with a safe area in the event our attack crew is met with a thermally aggressive fire coming at them and is forced to retreat.

Essentially, we “Wet to Protect”.

So, upon opening the door. Stop the nozzleman. What? Yes. Do another GO.. NO GO…. Entering into a known environment above 500 degrees in a heavily charged smoke condition is like climbing into the barrel of a gun. Why 500 degrees? If you think about it, what does our turnouts to protect us from? Radiant heat. Continuous exposures to thermal temperatures above 500 degrees erodes the protective elements of our turnout gear and limitations of our SCBA. In addition, many UL tests on SCBA’s and turnouts 500 degrees is used as a benchmark for protection for the wearer for only a short time before degradation or failure. So, if obtaining temperatures in a extreme fire condition (500 degrees+) at the door are found how long will crews be exposed to those temperatures while trying to make the hallway? See where I am going with this?

If extreme temperatures (500 degrees+) are encountered during your GO..NO GO test, order the hoseline opened to cool/ condition the environment you are about to enter. Perform another GO…NO GO Test. Temperatures should have dropped after the water application. If so, proceed in the attack. As the officer and crew make their way towards the fire area, slow the crew down and take intermittent GO.. NO GO test and cool and condition as you proceed towards the fire area. This also continues prior to climbing stairs, turning corners, entering adjacent rooms until reaching the fire area.

This GO…NO GO should be applied especially during Vent Enter Search Operations, as well.

“Smoke Showing”:

A term utilize by thousands of brothers on the fireground during the size-up. Well if we truly know how to “Read Smoke” what do we know about it? Survey the members of your agency..ask them what the interior temperature conditions are during light smoke, moderate smoke and heavy smoke. What about grey smoke, brown smoke, black smoke. I bet you get a variety of opinions.

Why not verbally convey via the radio to the IC the temperature findings on the GO..NO GO test? This will give the IC and idea of the potential fire he/she is confronting and can alter the fire attack, vent, and other operations accordingly.

Verbalizing the thermal conditions to the fireground is a more tangible way of describing interior conditions than simply describing smoke color or volume don’t ya think?

I hope this is starting to make sense to you by now…

By verbalizing the GO..NO GO Test, arriving units knows how intense a fire you are encountering and should be making their own plans, as well.

I tried using the GO..NO GO test during my fire attacks and found old habits were hard to break. My mask blacked out and I resulted to Old School firefighting of using my senses to determine the temperature levels. Upon reviewing the thermal data from the test I quickly discovered the environment we were entering was a NO..GO as we had thermal conditions of 800 degrees over our head. Luckily, with the aid of a fire curtain behind us keeping us in a “too rich” area and the fire never flashed over us.

As with any new idea there must be training to get this technique down. Try it in your next live fire training event I think you’ll be surprised at what you will see prior to entering.

By Trey Smith

FRC Instructor / Captain Ladder 1 Charlotte Fire Department

//

Posted in administration-leadership, command-leadership, ems-health-safety, Fire Dispatch, fire-prevention-education, fire-rescue-topics, firefighter-safety-health, firefighting-operations, fires, Kill the flashover, major-incidents, mass-casualty-incident, news, rescues, special-operations, technology-communications, Training, training-development, training-fire-rescue-topics, Uncategorized

Tagged , , , , , , , , , , , , , , , , , , , , ,

Have we forgotten Tradition in the fire service ?!?!?

First off let me start off by apologizing if this blog offends anyone. If you feel like you are easily offended , please do not read. Other than that, you have been warned. I decided to write this post in response to a Facebook post I saw just moments ago (I plan to keep this short and to the point). While being respectful I will keep the names of the fire department and station private.  But it is on Facebook, so how much privacy is there really? So what I saw was a fire station looking for ideas to replace their traditional “Wetting down ceremony” of their new apparatus . The reason they were looking for new ideas was, they were told that promoting a Wetting down ceremony was a violation of church and state. Correct me if I’m wrong , It states that a Separation of Church and State is the distance in the relationship of organized religion and the nation state. How in the crap is promoting or participating in a wetting down ceremony a organized religion??? It”s no different from our own government smashing a champagne bottle across the bow of a new war ship. Its the same thing and still is a common practice with our government.

Has today fire service changed so much that people forgot where they came from? As soon as they get into an administrative role it sucks the life and common sense out of them. Firefighters need to stand up for them selves and their rights. In the world of budget cuts, budget short falls , and administrative pay increases. Tradition is all we have left to keep the brotherhood! Now they are trying to take that away from all of us. No matter if you are Union or not, we all need to stick together. Do not forget where you came from!!

 

Note: Wetting down a new fire apparatus started many years ago. It is a way christening a new apparatus very much like the government does to its Navy ships. To learn more about how wetting down the new apparatus got started, I suggest you do some research ( I do not give out free history lessons, you have to work to get something you want). By doing so, you can learn for your self and pass it down to the ones beside, below, and above you.

//

//

//

Posted in administration-leadership, command-leadership, ems-health-safety, ems-topics, Fire Dispatch, Fire Safety, firefighter-safety-health, firefighting-operations, funding-staffing, hazmat, in-the-line-of-duty, line-of-duty, major-incidents, mass-casualty-incident, news, patient-management, rescues, special-operations, technology-communications, technology-communications-ems-topics, Uncategorized

Tagged , , , , , , , , , ,

The Creation of a Firefighter

When the Lord was creating Firefighters, he was into his sixth day of overtime when an angel appeared and said, “Your doing a lot of fiddling around on this one.”
And the Lord said “Have you read the specification on this person?
Firefighters have to be able to go for hours fighting fires or tending to a person that the usual every day person would never touch, while putting in the back of their mind the circumstances. They have to be able to move at a second’s notice and not think twice of what they are about to do, no matter what danger. They have to be in top physical condition at all times, running on half-eaten meals, and they must have six pairs of hands.”
The angel shook her head slowly and said, “Six pairs of hands…no way.”
“It’s not the hands that are causing me problems, ” said the Lord, “it’s the three pairs of eyes a Firefighter has to have.”
That’s on the standard model? ” asked the angel.
The Lord nodded. ” One pair that sees through the fire and where they and their fellow Firefighters should fight the fire next. Another pair here in the side of the head to see their fellow Firefighters and keep them safe. And another pair of eyes in the front so that they can look for the victims caught in the fire that need their help.”
“Lord” said the angel, touching his sleeve, ” Rest and work on this tomorrow.”
“I can’t, said the Lord, “I already have a model that can carry a 250 pound man down a flight of stairs and to safety from a burning building, and can feed a family of five on a civil service paycheck.”
The angel circled the model of the Firefighter very slowly, “Can it think?”
“You bet,” said the Lord. It can tell you the elements of a hundred fires; and can recite procedures in their sleep that are needed to care for a person until they reach the hospital. And all the while they have to keep their wits about themselves. This Firefighter also has phenomenal personal control. They can deal with a scene full of pain and hurt, coaxing a child’s mother into letting go of the child so that they can care for the child in need. And still they rarely get the recognition for a job well done from anybody, other than from fellow Firefighters.”
Finally, the angel bent over and ran her finger across the cheek of the Firefighter. “There’s a leak”, she pronounced.
“Lord, it’s a tear.”
“What’s the tear for?” asked the angel.
“It’s a tear from bottled-up emotions for fallen comrades. A tear for commitment to that funny piece of cloth called the American Flag. It’s a tear for all the pain and suffering they have encountered. And it’s a tear for their commitment to caring for and saving lives of their fellow man!”
“What a wonderful feature Lord, you’re a genius” said the angel.
The Lord looked somber and said “I didn’t put it there.”

Author Unknown

Posted in administration-leadership, command-leadership, Dispatch & Communications, Emergency Communications, EMS Dispatch, ems-health-safety, ems-topics, Fire Dispatch, fire-prevention-education, fire-rescue-topics, firefighter-safety-health, firefighting-operations, fires, funding-staffing, hazmat, in-the-line-of-duty, line-of-duty, major-incidents, mass-casualty-incident, news, patient-management, rescues, special-operations, technology-communications, Training, training-development, training-fire-rescue-topics, Uncategorized, vehicle-operation-ambulances, vehicle-operations-apparatus, videos, wildland

Tagged , , , , , , , , , , , , , , , ,

Out of Air Emergency (Last Chance Rescue Filter)

Out of Air Emergency The Last Chance Rescue Filter

You are in a dark, heat, smoke filled room, and you are taking your last breath. You think to yourself “now what?”. Your mind quickly goes to a check list of things to do. During this check list, your family comes to mind. “Is this it?” “I’m never going to see them again”. The nervousness and anxiety is starting to overcome your thoughts. “Is it really time for this?”, “I never thought I would use this”. As you grab your pouch, you take a deep breath (your last from your SCBA supply) and tear open the bag and pull out your Last Chance Rescue Filter and exchange your regulator for it. Now you have given yourself a second chance, the last chance.

The Last Chance Rescue Filter is a device designed to give firefighters a last chance effort to escape a smoke filled environment when their air supply runs outs. You may tell yourself that you will never allow yourself to run out of air. I’m sure the past LODD involving out of air emergencies would have loved the chance to use this device in time of need. I personally teach on Out of Air Emergencies and a Firefighter Confidence and Survival course through Fire and Rescue Concepts. But that does not mean that I will never be in a situation where I will run out of air. I personally carry a Last Chance Rescue Filter with me while I’m on duty. I even carry one while I perform live fire training, whether it is an acquired structure or a burn building, because you never know when you may need it. I’d rather have it and not need it, then need it and not have it.

 

Where did the Last Chance Rescue Filter come from?

 

Eric George, a firefighter in Connecticut, invented a lifesaving concept for firefighters trapped in an out of air emergency. He licensed his technology to Brookdale (a DuPont company in Canada) to bring his idea to market. This was the birth of the” EVAC Pro”. The EVAC Pro was a big hit and highly looked at as a premier escape device. But It was discovered that Brookdale’s packaging design on the “Evac Pro” and related products was fatally flawed, which resulted in a total product recall; this was the end of Brookdale and the “Evac pro”. So if you currently have an Evac Pro, I suggest that you remove it from service immediately. With a huge void left in firefighter survival,  Essex  recognized the importance of keeping Eric George’s concept alive by giving firefighters a new plan for out of air emergencies. Essex Industries  acquired Brookdale’s assets from DuPont along with the license to manufacture Eric George’s patented technology. Essex’s engineering team designed the Last Chance Rescue Filter® using materials that stand up to the rigors of fighting fires and successfully meet the EN403 standard through third party testing. Essex’s teamed up with Yale University to conduct a live burn in Hamden, CT to prove out the efficacy of the Last Chance and prove that there’s enough O2 in a structural fire to sustain life. Each day, firefighters are committing themselves to becoming leaders in the field by utilizing proven technology and solidifying their plan for out of air emergencies.

 

Is the Last Chance Rescue Filter compatible with my SCBA?

Currently the Last Chance Rescue Filter is compatible with the following

SCOTT SCBA MASKS: AV-2000, AV-3000, SCOTT-O-VISTA

DRAEGER SCBA MASKS: PANORAMA NOVA-P, FUTURA P, F2P, FPS 7000

MSA SCBA MASK: FIREHAWK

SPERIAN SCBA MASKS: TWENTY TWENTY PLUS

ISI SCBA MASKS: RDV FACEMASKS

How does it work?

 

Contaminated air is drawn through the Last Chance Rescue Filters three main layers of protection:

• N95 pleated filter (Captures solid matter, soot and particulates)

• Activated Carbon Filter (Scrubs or absorbs the toxic gases)

• Manganese Dioxide/Copper Oxide (hopkalite) (Converts CO to Carbon Dioxide)

 

The makers of the Last Chance Rescue Filter certify their product to filter out the harmful particles and smoke for 15 minutes. This does not mean that you have an extra 15 minutes to allow you to stay in and work longer. But this means that the time needed for your escape or the incoming RIT team is there. Understand that the Last Chance Rescue Filter does not give you more 02. It only filters out the harmful particles in the atmosphere for short amount of time. Individuals wishing to use this product need to undergo training with the training unit in a non-smoke environment before In-service status the Last Chance Rescue Filter. The Last Chance Rescue Filter is encased in a vacuumed sealed moisture barrier and has a shelf life of 5 and ½ years from the date of manufacture. There is also a protective cover designed to carry and protect the filter. The protective cover can be attached to a SCBA waist belt or a bail out belt of some kind. Firefighters must understand that they need to take care of this piece of equipment just like any other piece used for life safety. I suggest that firefighters do a daily and after run check of the device to make sure the filter and or vacuum sealed moisture barrier has been damaged in any way shape or form. Once the filter has been used once or the moisture barrier has been breached, then the used of the filter is now void. Remember the main killer of the EVAC Pro was the fact that moisture was allowed to enter into the filter before use. The makers of the Last Chance Rescue Filter will replace any filter that is used in any firefighter escape in an actual incident.

 

When would you use it?

 

• A firefighter becomes lost and disoriented and is running out of air. There is not enough time to get out.

• With the Last Chance Rescue Filter® , he would be able to take the last breath of supplied air, clip in the Last Chance Rescue Filter® , have 15 minutes to get out and/or continue to update RIT for rescue.

• Also, his mask remains ON, ready for RIT to replace the filter with supplied air versus RIT having to replace the firefighters mask.

• A firefighter’s air pack becomes trapped and he can’t get out of the jam.

Only in the extreme case should a firefighter remove an air pack. Without the air pack, the firefighter has no PASS device, transfill , or buddy breathing hose.

• By donning the Last Chance Rescue Filter® the firefighter can escape without the air pack!

• A firefighter experiences a sudden SCBA failure and suddenly you’re out of air.

• Don the Last Chance Rescue Filter® and get out!

• RIT team is called in for multiple downed firefighters and there is not enough supplied air.

• Carry additional Last Chance Rescue Filter® in RIT bags for this circumstance.

 

I invite every firefighter to watch to video below and let us know if you have any question.

You can purchase the Last Chance Rescue Filter on our online store or contact Eric Stroud at estroud@fireandrescueconcepts.com

We also have incorporated the Last Chance Rescue Filter with our Firefighter Confidence and Survival Training

Posted in administration-leadership, command-leadership, Dispatch & Communications, Emergency Communications, EMS Dispatch, ems-health-safety, ems-topics, Fire Dispatch, Fire Safety, fire-rescue-topics, firefighter-safety-health, firefighting-operations, fires, funding-staffing, in-the-line-of-duty, line-of-duty, major-incidents, mass-casualty-incident, patient-management, rescues, special-operations, technology-communications, technology-communications-ems-topics, Training, training-development, training-fire-rescue-topics, Uncategorized, vehicle-operations-apparatus, videos

Tagged , , , , , , , , , , , , , , , , , , ,

Christmas Tree Safety

As we approach another Christmas season, we need to always remember safety. During this time is prime for traffic accidents , fires, falls, and other traumatic incidents. But today we are going to focus on Christmas Tree Safety. It seems every year that the public is so excited that they rush the season by putting their tree in their homes earlier and earlier. I have even heard of people putting out their trees two weeks before the American Thanksgiving Holiday. We are going to cover the hazards of two types of Christmas Trees that are found in homes today, Real and Fake.

 

Real Christmas Tree

There is nothing like the joy and the smell of putting up a real Christmas Tree. According to FEMA real Christmas trees account for roughly 250 fires annually. That may seem like a small number, but out of the 250 fires , roughly 14 people die. Now that is 250 fires too many. Its not even worth one life. Not to mention the 14 million dollars of damage they cause to house holds. NFPA and FEMA offer suggestions when dealing with real trees.

 

What about Fake Christmas Trees?

There are many people that decide to buy a fake tree. Many reason are due to, budget, allergies, and etc. What ever the reason may be, over 10 million fake trees where sold world wide in 2003. Most fake trees that are imported to the United States are from China. Fake trees are typically made from plastic and other synthetic material when exposed to a heat or ignition will catch fire.

Below are some tips to help you during this Christmas Season when dealing with fake and real Christmas trees.

 

1st. Water your Tree!! ( a dry tree is a fire bomb waiting to explode )  all it needs is an ignition source to get it going. Make sure your real tree has a fresh cut of one to two inches, so that it may better absorb the water.

2nd. Never have lit candles near your tree. This provides a ignition source to all trees.

3rd. Placement of the tree is critical. Becareful about placing your tree around vents and fire places. They can dry out your tree faster and can be a ignition source for your tree.

4th. Check your lights. Make sure you are using the newest brand of lights that are on the market. Newer lights are manufactured to a standard of care than older lights were. If you have older lights, it may be time to replace them.

5th. Do not over load your circuits and outlets. Most lights allow you to plug multiple strands together. This it self may cause a short or a spark. Its best to use a power strip with a built in serge protector, drop cords are a no no. We have all seen the movie a Christmas Story, pay special attention to scene of when the old man gets his lamp and he attempts to plug it in to a overloaded outlet.

6th. When your real tree has dried out, it is time to get rid of it. The longer a dry tree stays in your home, the greater the chance you are taking.

"The video clip above from the Building and Fire Research Laboratory of the National Institute of Standards and Technology illustrates what happens when fire touches a dry tree. Within three seconds of ignition, the dry Scotch pine is completely ablaze. At five seconds, the fire extends up the tree and black smoke with searing gases streaks across the ceiling. Fresh air near the floor feeds the fire. The sofa, coffee table and the carpet ignite prior to any flame contact. Within 40 seconds "flashover" occurs – that's when an entire room erupts into flames, oxygen is depleted and dense, deadly toxic smoke engulfs the scene." Quoted from FEMA

DISCLAIMER: This post is for informational purposes only. Information and research was taken from NFPA, FEMA, and the Nation Christmas Tree Safety Association. This post was short and to the point. We suggest that everyone to reaserch the dangers of Christmas Trees, real or fake. We help that everyone have a safe and Merry Christmas!!

 

Posted in ems-topics, Fire Safety, fire-prevention-education, fire-rescue-topics, firefighter-safety-health, firefighting-operations, fires, major-incidents, news, rescues, special-operations, training-development, training-fire-rescue-topics, videos

Tagged , , , , , , , , , , ,

Hooks and Hoses, Let’s Work Together

Capt. Trey Smith

So you want to be a truckie, or even a nozzleman? Assuming these roles takes tremendous knowledge of the responsibilities and expectations to be performed which should not be taken lightly. These positions will make or break a good offensive fire attack.

These positions are the workhouses of the fireground and one does not perform or work efficiently without the other. For the moment, let's try to put aside our egos and focus upon the task at hand of getting the wet stuff on the red stuff. Following two large scale incidents in my first due area in recent months, I have had time to reflect upon some of our successes and our shortcomings of two identical fires involving mutli-family occupancies or large scale residences.

I started out my career assigned to several active engine companies and had some great officers and firefighters I have worked with throughout my tenure. I became a truckie after making Captain and enjoy the challenges of truck & rescue work. But in my 30+ years within the fire service, I have grown frustrated at the reality of having lots of nozzlemen and hose jockeys but few ceiling pullers and the lack of coordination between the two functions.

While true, chief and line officers are expected to direct the symphony of crews working to contain a rapidly progressing fire, many firefighters are under the fallacy tactics training is solely for white & gold shields and doesn't apply to the tailboard firefighter. But the reality is, these positions (nozzleman and celing pullers) will work without direct supervision of the line officer. This results in the IC relying upon the decisions of a firefighter to decide upon the appropriate hoseline and to accurately select the placement of a critical position to defend areas of non-fire involvement. During particularly large scale fires where the fire is "running the attic", several key tactics must occur in a timely fashion or our brothers & sisters will inevitably be overrun and will be losing the battle to stop the forward progression of a rapidly developing fire.

To understand fire travel is to fully grasp the concept of fluid travel and smoke reading. Fire is a fluid that will always follow the path of least resistance. Therefore, as the saying goes…" where there is smoke there is fire", and if gone unchecked or reversed the fire will eventually show itself sometimes more than we expect. So, our hooks and hoses must possess the ability to predict the stage of the fire, the level of heat production, and where it is headed based upon reading the color of smoke, the intensity, and the rate it is leaving the structure will impact the success of our attack.

Let's face it… we have all been there during the heat of the engagement… lots of screaming. noise, confusion, darkness, heat, stress… you name it. We open up the ceiling to get the nozzle into to position within the cock-loft or attic only to see the distinguishable signs of heavy fire rolling across the structural members (truss) above our heads. What should this indicate to the nozzleman and truck crews? And what immediate actions should be taken when these cues are indicated?

1. Observe the direction of the fire. Where is coming from and where is it going? Look at the amount of fire, heavy, moderate, or light?

2. Radio back to IC/Command the fire has passed your attack team. The IC continually needs this feedback in order to re-assess his strategy/tactics, his situation and resource status. He/she may prioritize the incident needs based upon your feedback or request/re-direct additional resources.

3. You are standing in a potential collapse area! Get out from underneath such areas! Because the fire is continually attacking the structural members, we lose valuable seconds of integrity trying to breach walls and ceiling only for them to come crashing down on our personnel. Lightweight wood and steel bar joist floors and roofs don't wait for you. They are coming down whether you are ready or not.

4. Re-Position your attack.

Why try to hold an ineffective position when the the fire is burning behind you? Truckies…Make inspection holes along the ceiling until you see no fire in the attic before deciding where to take up your new posture. when you pull the ceiling and see heavy smoke banking down on you, note the color of the smoke. Heavy black smoke indicates "Black Fire" This means you have high heat and are close to the fire which will be in your area in a matter of seconds! Moderate smoke provides some time to open up large areas and allows time to get hoselines in place. Make sure the nozzleman has the tools he/she needs to mount the offensive. Nozzlemen and Hose Jockies…Bring the attic ladder for goodness sake, don't rely on the truck company to bring it, they enough to do already! After all that IS where the fire is located. Have the hooks open up large areas in multiple rooms and hallway where the nozzleman can hit the fire as it advances from the floor. This is critical if using a large caliber stream such as a 2 1/2". Ever tried manipulating a 2 1/2" in an smaller room or attic space? The larger sized lines will not make the turns in a residence and should anticipate working from the floor and in a hallway or open space.

5. Find the seat of the fire and extinguish it! Often times, we forget that while trying to cut the fire off it isn't going to go out until someone cut's the head off the dragon! Get a line on the seat /origin of the fire and things will improve dramatically.

6. Maintain your egress!!! While engaging the forward progression of the fire, we forget the fire we passed may actually be cutting off our ability to evacuate. Get a back-up line in place, knock-down any fire impinging upon your escape route, or order the evacuation of all crews of an impending collapse or flashover of the area. If you are operating in the hot zone always have two or more ways to escape.

7. Listen to the radio! If you hear things being said such as "flowing the aerial", "Master Stream", "Defensive", "Roof Sagging", "partial collapse"… Don't hesitate to get you and your personnel to the hell out of a potentially catastrophic event.

8. Practice "Pro-actionarism" Pro-Actionarism is the act of being pro-active, taking initiative, taking action. Recognize when situations are going bad and make the necessary steps to mitigate them or make the decision to abandon the effort.

Posted in command-leadership, fire-prevention-education, fire-rescue-topics, firefighter-safety-health, firefighting-operations, fires, major-incidents, news, rescues, special-operations, training-development, training-fire-rescue-topics, Uncategorized, vehicle-operations-apparatus